E⁴ rates your building's carbon intensity (kgCO₂e/m², stages A1–A5) on a scale from A++ to G, similar in spirit to energy labels on appliances.
The bands
- A++ under 100 · A+ under 200 · A under 300 kgCO₂e/m², best-in-class, usually mass timber or heavily optimised design.
- B under 400 · C under 500, good practice; achievable with low-carbon concrete and efficient structure.
- D under 600 · E under 700, typical conventional construction.
- F under 800 · G above 800, carbon-intensive; worth a serious design review.
The bands are indicative guideposts based on published benchmark ranges, not a certification. Use them to track progress: moving from D to B on the same brief is a real, meaningful achievement.
Tip: use what-if swaps on any report to see which material changes would move your rating the most.
Alignment with LETI 2021 and RIBA 2030
LETI 2021 publishes A++ to G embodied carbon bands for offices, residential, education and retail. For offices, for example: A++ under 100, A under 350, C under 600 and G under 1,300 kgCO₂e/m². E⁴ reports show the LETI panel only for these building types.
- RIBA 2030 offices: current practice ~1,400 → 2025 target 970 → 2030 target 750 kgCO₂e/m².
- RIBA 2030 schools: ~1,000 → 675 → 540 kgCO₂e/m².
- RIBA 2030 residential: ~1,200 → 800 → 625 kgCO₂e/m².
Note: RIBA targets cover stages A–C, so an A1–A5 result is a partial comparison: a fast design-stage indicator, not a compliance check.